Homepage | Company Profile | Lab Introduction | Compliance Service | Certification Download | Links | Contact Us | Chinese
Quick Link
1.BSMI 
2.NCC 
Lab Introduction
 Gestek » Lab Introduction

【Lin Kou lab】
Lin Kou testing lab includes the functions for testing EMC, RF, Video broadcasting and DVB-T receiver function
Test field Quantity Photo
3/10m Open site 6 A1 Open site
A2 Open site
B1 Open site
B2 Open site
C1 Test site
C2 Test site
Anechoic chamber for electromagnetic wave (Including 966*1) 5 Inner photo
Appearance photo  
Shielded room for electromagnetic wave 7 EMS test field
Conduction interference test field  
Anechoic chamber for wireless product electromagnetic wave 1 Wireless product electromagnetic wave test filed 
Video product RS isolation room 1 Video product EMS test field 
Service Item:
  • Worldwide EMC Compliant Service & Consultation
  • Worldwide Safety Approval Service & Consultation- Coordinated with Safety Lab
  • Worldwide Wireless Product Compliant Service & Consultations
  • TV & Broadcasting Product Compliant Service & Consultations
  • British D-BOOK, European Union E-BOOK and BSMI ground digital TV receiver performance
     test Compliant Service & Consultations
  • Worldwide telecom product Compliant Service & Consultations – Coordinated with telecom labs
  • Turn-key project for EMC compliant chamber and test fields, included planning 、 construction、
     system integration, approval application and after-sale service.
  • EMC debugging service for the product
  •  
     
    【Hsinchu lab】
    In order to provide better and more convenient service to the client in Hsinchu Technology park and the ones located in middle and southern Taiwan, Hsinchu lab, founded in July, 2004, concentrates and specialized in EMC Layout consultation and debugging task forces.
    Test field Quantity Photo
    3m EMC non-reaction chamber 2 Inner photo
    Appearance photo  
    ESD Immunity test field 1 ESD Immunity test field 
    Conduction and interference test field 1 Conduction and interference test field 
  • Worldwide EMC Compliant Service & Consultation
  • Worldwide Safety Approval Service & Consultation- Coordinated with Safety Lab
  • Worldwide Wireless Product Compliant Service & Consultations
  • TV & Broadcasting Product Compliant Service & Consultations
  • Formulation and construction of EMC test field, system integration, approval application and
     after-care service.
  • EMC debug service for the product
  • Electro-magnetic Radiated Emission Interference Measurement
  • Electro-magnetic Conducted Emission Interference Measurement
  • ESD Immunity Test
  •  
     
    【Service item/ test method/ range】
    Service item test method range
    Electronic and Electric approval FCC Method-47 CFR Part 15 Subpart B
  • 9 kHz-40 GHz
  • Low power RF Electric Machinery approval

  • 47 CFR FCC Part 15 Subpart C
  • NCC LP0002
  • 9 kHz-40 GHz
  • Industial,scientific,medical equipment approval
  • FCC Method-47 CFR Part 18
  • 150 kHz to 26.5GHz
  • Electromagnetic disturbance characteristics of industrial, scientific and medical radio-frequency equipment EMI approval
  • CISPR 11
  • EN 55011
  • Conduction Interference:
     9 kHz-30 MHz
  • Radiation Interference:
     9kHz-26.5 GHz
  • Audio and television broadcast receivers and related equipment- related equipment- radio frequency interference approval
  • CISPR 13
  • EN 55013
  • CNS 13439
  • AS/NZS CISPR 13
  • Conduction Interference:
     150 kHz-30 MHz
  • Radiation Interference:
     30 MHz-1 GHz
  • Antenna Point Voltage
     Interference:
     30 MHz -2.15 GHz
  • RF Output Terminal
     Interference:
     30 MHz -2.15 GHz
  • Electric appliance and serial approval
  • CISPR14-1
  • EN 55014-1
  • CNS 13783-1
  • AS/NZS CISPR 14.1
  • Conduction Interference
     :150 kHz-30 MHz
  • Interference Voltage:
     30 MHz-300 MHz
  • Click Rate:
     150K, 500K, 1.4M, 30MHz
  • Electrical lighting and similar equipment approval
  • CISPR 15
  • EN 55015
  • CNS 14115
  • AS/NZS CISPR 15
  • Conduction Interference:
     9 kHz-30 MHz
  • Magnetic Field Interference:
     9 kHz-30 MHz
  • Insertion Loss:
     150 k-1605 kHz
  • Uninterruptible power system
  • EN 62040-2
  • IEC 62040-2
  • AS 62040.2
  • CNS 14757-2
  • 150 kHz-26.5GHz
  • Sound and television broadcast receivers and associated equipment EMS approval
  • CISPR 20
  • EN 55020
  • CNS 14409
  • Testing Voltage:
     100~270Vac(single phrase)
  • Testing Current:
     16A
  • 150kHz to 1GHz
  • Information technology system and equipment. approval
  • CISPR 22
  • EN 55022
  • CNS 13438
  • AS/NZS CISPR 22
  • Conduction Interference:
     150 kHz-30 MHz
  • Radiation Interference:
     30 MHz-26.5 GHz
  • Technical specification for digital terrestrial television receivers
  • CNS14972
  • D-BOOK
  • E-BOOK
  • 470MHz~850MHz

  • Information technology equipment EMS approval
  • CISPR 24
  • EN 55024
  • Refer to the Following  IEC61000-4 Serial

    Harmonic Current EmissionsInterference Approval

  • IEC 61000-3-2
  • EN 61000-3-2
  • AS/NZS 61000.3.2
  • Test voltage :100-250 V (single phase)
  • Test current :0-16 A
  • Harmonic order:(1 to 40) orders
  • Voltage Fluctuation and Flicker Measurement approval

  • IEC 61000-3-3
  • EN 61000-3-3

  • AS/NZS 61000.3.3
  • Test voltage :100-250 V (single phase)
  • Test current :0-16 A
  • Electrostatic discharge Immunity test
  • IEC 61000-4-2
  • EN 61000-4-2
  • CNS 14676-2
  • Air Discharge:
     0-25 kV
  • Contact Discharge:
     0-10 kV
  • RF radiated fields immunity test
  • IEC 61000-4-3
  • EN 61000-4-3
  • ENV 50204
  • CNS 14676-3
  • Frequency Range:
     27 MHz-1 GHz
  • Field Strength:
     10V/m(Max)
  • Frequency Range:
     1GHz-2.5 GHz
  • Field Strength:
     3V/m(Max)
  • AM Compensation
  • Frequency Range:
     895 MHz-905 MHz
  • PM Compensation
  • Electrical fast transient/burst immunity test
  • IEC 61000-4-4
  • EN 61000-4-4
  • CN S14676-4
  • Interference Voltage:220 V-5.5 kV
    Surge Immunity testing
  • IEC 61000-4-5
  • EN 61000-4-5
  • CNS 14676-5
  • Open circuit voltage:0-6 kV

    Short circuit current:125A-3300A

    Conducted disturbances immunity
  • IEC 61000-4-6
  • EN 61000-4-6
  • CNS 14676-6
  • 150 kHz-230 MHz
  • AM Compensation, 10 Vrms
  • Magnetic field immunity
  • IEC 61000-4-8
  • EN 61000-4-8
  • CNS 14676-8
  • Continuous Magnetic Field:
    1 A/m-100 A/m
    Voltage dips, voltage interruptions and voltage variations immunity test
  • IEC 61000-4-11
  • EN 61000-4-11
  • Voltage Interruption:100 %
  • Voltage Dips:0-100 %
  • Voltage Variations:
     Standard Nordstrom Waveform
  • Oscillatory wave immunity test
  • IEC 61000-4-12
  • EN 61000-4-12
  • GB/T 17626.12
  • Testing equipment power
     range:
  • Ringwave 0.5μs/100 kHz,
     0-6 kV
  • Osc. Wave 75 ns/100 kHz
     and 1 MHz, 0-2.7 kV
  •